Subscribe our newsletter here and get 10%* off your next purchase! (terms & conditions*)
2-1209-550

Strep-Tactin® Superflow® high capacity column

Gravity flow column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins

€296.00*

Content
Strep-Tactin® Superflow® high capacity columns are ready-to-use for purifying strep-tagged proteins below 90 kDa via affinity chromatography. These gravity flow columns contain a highly cross-linked agarose coated with streptavidin variant Strep-Tactin®, which captures proteins fused to a Strep-tag®II or a Twin-Strep-tag®.  A straightforward purification principle results into a highly pure (>95%) protein preparation. After regeneration, the columns can be used multiple times.
Please note that biotinylated proteins also bind to Strep-Tactin® Superflow® high capacity. If biotinylated proteins are expected, use BioLock. Furthermore, if large (sample and/or buffer) volumes have to be applied, we recommend our WET FRED system.

For a resin overview with recommendations, browse our resin specifications.

Specifications

Bead Size: 60 - 160 µm spherical
Biotin Binding Capacity: > 900 nmol/ml resin
Dynamic Protein Binding Capacity: 7 mg/ml resin
Exclusion Limit: 6 x 10^6
Form: Pre-packed gravity flow column
Possible Application: Protein purification of Strep-tag®II and Twin-Strep-tag® fusion proteins
Specificity: Twin-Strep-tag®; Strep-tag®II; cross reactivity: biotin
Support: 6% agarose, crosslinked

Shipping information

Storage: 2-8 °C
Stability: 6 months after shipping
Shipping: Room temperature

Accessories

BioLock
Content: 50 ml
Biotin blocking solution for lysates and culture supernatants
Strep-Tactin® Buffer Set
Strep-Tactin® purification buffer set
Buffer W (10x)
Strep-Tactin® and Strep-Tactin®XT wash buffer
Buffer E (10x)
Strep-Tactin® elution buffer with desthiobiotin
Buffer R (10x)
Strep-Tactin® regeneration buffer with HABA

Related Products

Strep-Tactin® Superflow® high capacity FPLC column
Content: 1 ml
FPLC column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin® Superflow® high capacity column
Content: 5 x 0.2 ml
Gravity flow column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin® Superflow® high capacity resin
Content: 4 ml
50% suspension to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin® Superflow® resin
50% suspension to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin® MacroPrep® resin
50% suspension to purify Strep-tag®II or Twin-Strep-tag® fusion proteins