2-5012-001

Strep-Tactin®XT 4Flow® column

Gravity flow column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Quantity Unit price
1-4
€73.50*
From 5
€66.00*
Content

Strep-Tactin®XT 4Flow® columns contain a 4% agarose coupled with the streptavidin variant Strep-Tactin®XT and are applicable for purification of Strep-tag®II or Twin-Strep-tag® fusion proteins via gravity flow. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (> 95%), and highest binding affinity, the resin is recommended for all protein classes, especially for low abundant or challenging proteins. The low concentrated agarose allows for the simple attachment of larger proteins to the stationary phase, making it particularly suitable for purification of high-molecular-weight targets. 
To reduce the waiting period during the sample and buffer application, the use of the application aid WET FRED is recommended.

Specifications

Bead Size: 50 - 150 µm spherical
Dynamic Protein Binding Capacity: 5 mg/ml resin
Form: Pre-packed gravity flow column
Possible Application: Protein purification of Strep-tag®II and Twin-Strep-tag® fusion proteins
Specificity: Twin-Strep-tag® and Strep-tag®II
Support: 4% agarose, crosslinked

Shipping information

Storage: 2-8 °C
Stability: 6 months after shipping
Shipping: Room temperature

Accessories

WET FRED Set
Application aid for large volumes of lysates or culture supernatants
Buffer W (10x)
Strep-Tactin® and Strep-Tactin®XT wash buffer
Buffer BXT (10x)
Strep-Tactin®XT elution buffer
Biotin
Biotin powder for preparation of Strep-Tactin®XT elution buffer
Buffer XT-R
Strep-Tactin®XT regeneration buffer
Strep-Tactin®XT Buffer Set
Strep-Tactin®XT purification buffer set

Related Products

MagStrep "type3" XT beads
Magnetic beads (5% suspension) to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin®XT 4Flow® high capacity Spin Column Kit
For rapid purification of Strep-tag®II and Twin-Strep-tag® fusion proteins
Empty Spin Columns
For rapid protein purification with Strep-Tactin®XT 4Flow® high capacity
Strep-Tactin®XT 4Flow® FPLC column
FPLC column to purify Strep-Tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin®XT 4Flow® resin
50% suspension to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin®XT 4Flow® high capacity column
Gravity flow column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin®XT 4Flow® high capacity FPLC column
FPLC column to purify Strep-tag®II or Twin-Strep-tag® fusion proteins
Strep-Tactin®XT 4Flow® high capacity resin
50% suspension to purify Strep-tag®II or Twin-Strep-tag® fusion proteins